Sabtu, 26 Mei 2012

Lung Function Of Patients With Severe Emphysema Improved With Tiny Implanted Coil

Lung Function Of Patients With Severe Emphysema Improved With Tiny Implanted Coil

Main Category: Respiratory / Asthma
Also Included In: Medical Devices / Diagnostics;  Clinical Trials / Drug Trials
Article Date: 26 May 2012 - 0:00 PDT

email icon email to a friend   printer icon printer friendly   write icon opinions   <!-- rate icon rate article


Patient / Public:not yet rated

Healthcare Prof:not yet rated


A tiny, resilient metal wire designed to gather and compress diseased lung tissue may offer relief to patients with severe heterogeneous emphysema, a subtype of the disease that involves specific, usually isolated areas of the lungs, according to the results of a multicenter international trial conducted in the Netherlands, Germany and France. The wire, called a lung volume reduction coil (LVRC), can be easily implanted and is designed to take the place of more invasive procedures used to improve the lung function of emphysema patients.

The study was presented at the ATS 2012 International Conference in San Francisco.

"Our results indicate that LVRC treatment is technically feasible in both upper and lower regions of the lung in patients with severe heterogeneous emphysema, and results in significant improvements in pulmonary function, exercise capacity and quality of life, with an acceptable safety profile," said study lead author Dirk-Jan Slebos, MD, pulmonary physician at the University Medical Center Groningen (UMCG), The Netherlands.

Lung volume reduction is performed in patients with emphysema in an effort to isolate diseased lung tissue and allow healthy lung tissue to expand and function more efficiently, which in turn helps the patient to breathe and function better. Because heterogeneous emphysema involves different areas, or lobes, of the lung, surgery to contain diseased lung tissue can be complicated and extensive. Use of wire coils, which can be implanted in relatively noninvasive bronchoscopic procedures, is emerging as a more effective, and safer, option than surgery for these patients. Coils are compressed during implantation, and expand to their original shape once implanted in the lung tissue.

Although a previous single-center trial showed LVRC to be safe and effective in patients with severe upper-lobe emphysema, Dr. Slebos said this study involved patients treated at 11 different healthcare centers, and explored the safety, efficacy and feasibility of LVRC in both upper and lower lobes.

The study enrolled 53 patients who underwent 101 LVRC procedures, including 46 bilateral (both lungs) procedures and nine unilateral procedures. In each procedure, the clinicians implanted from eight to 14 coils, resulting in a study total of 1,070 coils being implanted. Safety was evaluated by recording all adverse events that occurred within the first 30 days following treatment, as well as those that occurred between 30 days and six months of treatment. Efficacy was measured by quality-of-life questionnaires, pulmonary function testing and exercise testing, all performed six months following treatment. Reported adverse events included exacerbation of chronic obstructive pulmonary disease (COPD), pneumonia, collapsed lung, chest pain and mild hemoptysis, or coughing up blood, which could be managed with standard care.

The researchers found that LVRC treatment resulted in significant improvement in respiratory measurements at six months, especially in patients whose lungs were severely hyperinflated. In this group, LVRC therapy resulted in significant improvements in lung function, hyperinflation, exercise capacity and quality of life measurements. In fact, severe hyperinflation at baseline appeared to be an indicator of better outcomes, Dr. Slebos noted.

"Hyperinflation of lung tissue is one of the key pathophysiological features of emphysema that is responsible for shortness of breath, and its magnitude seems to be a good indicator of successful LVRC treatment," he said.

Dr. Slebos said the trial is ongoing and continues to collect data.

"The results so far indicate that the LVRC is a safe and effective choice for treating patients with severe heterogeneous emphysema where current medical treatment fails, and as we continue to collect follow-up data, we hopefully will have a more complete profile of its applications in this patient population," he said.

"Lung Volume Reduction Coil Treatment For Patients With Severe Heterogeneous Emphysema, A Multicenter Feasibility Trial" (Session D15; Abstract 27924)
* Please note that numbers in this release may differ slightly from those in the abstract. Many of these investigations are ongoing; the release represents the most up-to-date data available at press time.
Abstract 27924
Lung Volume Reduction Coil Treatment For Patients With Severe Heterogeneous Emphysema, A Multicenter Feasibility Trial
Type: Scientific Abstract
Category: 09.08 - COPD: Non - Pharmacological Treatment (CP)
Authors: D.-J. Slebos1, S. Blaas2, G. Deslee3, W. Geseirich4, F.J. Herth5, J. Hetzel6, M. Hetzel7, R. Kessler8, C.-H. Marquette9, M. Pfeifer2, F. Stanzel10, C. Witt11; 1University Medical Center Groningen - Groningen/NL, 2Klinikum Donaustauf - Donaustauf/DE, 3Hopital Maison Blanche CHU - Reims/FR, 4Asklepios - Gauting/DE, 5Thorax Klinik - Heidelberg/DE, 6UKT University Hospital - Tuebingen/DE, 7Krankenhaus vom Roten Kreutz - Stuttgart/DE, 8CHRU de Strasbourg - Strasbourg/FR, 9Hopital Pasteur, CHU Nice - Nice/FR, 10Lungenklinik - Hemer/DE, 11Charité - Universitätsmedizin Berlin - Berlin/DE
Abstract Body
Rationale: The Lung Volume Reduction Coil (LVRC) is a bronchoscopic device made of self-expandable nitinol wire for the treatment of emphysema. A previous single center pilot study showed safety and efficacy in severe upper-lobe emphysema. In this study we investigated the feasibility, safety and efficacy of LVRC treatment in a multicenter cohort trial design in patients with severe upper or lower lobe heterogeneous emphysema.
Methods: 53 patients (29F/24M, 61.5yrs (±7.2)), FEV1 30.2%pred (±6.7%), RV 243%pred (±52%), RV/TLC 66.2 (±9.5), SGRQ 62.3 (±12.6) were bronchoscopically treated under general anesthesia using fluoroscopy with LVRCs (PneumRx, USA) in either one or two lungs (in two sequential procedures) in 11 European centers. Safety was evaluated by recording all adverse events (AEs), efficacy was measured by questionnaires, pulmonary function and exercise testing at 6 months post treatment. The trial is ongoing.
Results: 101 LVRC procedures were performed (46 bilateral, 9 unilateral). 40 patients were treated in the upper lobes and 13 in the lower lobes. A total of 1070 coils were placed with median 10 coils (range 8-14) placed per procedure in 48±24 min. Adverse events 30 days â€" 6months after the procedure were: COPD exacerbation (n=21), pneumonia (n=11), pneumothorax (n=3), chest pain (n=3), and mild hemoptysis (n=1). LVR-coil treatment resulted at 6 months in the overall group in a Î"FEV1 +13% (±4.9%), Î"RV -0.44L (±0.16), Î"6MWD +35m (±12) and Î"SGRQ -10 points (±2.3). RV%pred at baseline correlated significantly to improvement in RV after treatment (r2=0.453, p220%pred, the 6 months results are: Î"FEV1 +19% (±6.8%), Î"RV -0.57L (±0.21), Î"6MWD +42m (±14), and Î"SGRQ -14 points (±3.1).
Conclusion: LVRC treatment is technically feasible in both upper and lower lobe severe heterogeneous emphysema and results in significant improvements in pulmonary function, exercise capacity and quality of life, with an acceptable safety profile. High RV at baseline seems to be an indicator of better outcome.
Funded by: PneumRx Inc, Mountain View, CA
American Thoracic Society Please use one of the following formats to cite this article in your essay, paper or report:

MLA


APA

Please note: If no author information is provided, the source is cited instead.



Add Your Opinion On This Article

'Lung Function Of Patients With Severe Emphysema Improved With Tiny Implanted Coil'

Please note that we publish your name, but we do not publish your email address. It is only used to let you know when your message is published. We do not use it for any other purpose. Please see our privacy policy for more information.

If you write about specific medications or operations, please do not name health care professionals by name.

All opinions are moderated before being included (to stop spam)

Contact Our News Editors

For any corrections of factual information, or to contact the editors please use our feedback form.

Please send any medical news or health news press releases to:

Note: Any medical information published on this website is not intended as a substitute for informed medical advice and you should not take any action before consulting with a health care professional. For more information, please read our terms and conditions.



MediLexicon International Ltd Logo

Privacy Policy | Terms and Conditions

MediLexicon International Ltd
Bexhill-on-Sea, United Kingdom
MediLexicon International Ltd © 2004-2012 All rights reserved.
MNT (logo) is the registered EU trade mark of MediLexicon Int. Limited.

Everyday Health Network back to top | home | privacy policy

MediLexicon International Ltd Logo MediLexicon International Ltd
Bexhill-on-Sea, United Kingdom
MediLexicon International Ltd © 2004-2012 All rights reserved.
MNT (logo) is the registered EU trade mark of MediLexicon Int. Limited.

Tidak ada komentar:

Posting Komentar